Semi-automatic volumetry of solid pulmonary nodules improves the interobserver consistency of Lung-RADS score
Author:
Affiliation:

Department of Radiology, Xijing Hospital of Air Force Medical University

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 研究3D-Slicer软件实性肺结节体积测量对不同观察者在肺部影像报告数据系统(lung CT screening reporting and data system,Lung-RADS)分类一致性中的影响。方法 纳入76例患者中的76个实性结节。由3位放射科医师分别采用手动和3D-Slicer软件半自动体积测量方法获得结节的直径与体积,并转化为相应的Lung-RADS评分,其中2分为阴性,3分及以上为阳性。采用同类相关系数(intraclass correlation coefficient,ICC)及Bland-Altman指数来评价观察者间直径与体积测量的一致性,Kappa分析评价观察者间Lung-RADS评分及阳性/阴性组间的一致性。结果 ICC分析结果显示手动直径测量的一致性(0.994~0.996)明显低于半自动体积测量的一致性(0.997~0.998),同时Bland-Altman指数分析结果显示手动直径测量的偏倚高于半自动体积测量。采用半自动体积测量,能够比手动直径测量明显提高观察者间Lung-RADS评分及阳性/阴性之间的一致性(0.963~0.975及0.957~0.977 vs. 0.833~0.866及0.863~0.892)。结论 3D-Slicer半自动体积测量能够提高实性肺结节观察者间大小测量的一致性,相应的Lung-RADS分类一致性也随之提高。

    Abstract:

    Objective To study the effect of solid pulmonary nodules volume measurement by 3D-Slicer software on the interobserver consistency of lung CT screening reporting and data system(Lung-RADS) categories.Methods Seventy-six solid nodules from 76 patients were included in this study. The diameter and volume of nodules were obtained by three radiologists using manual and 3D-Slicer software semi-automatic volume measurement methods,respectively,and the raw data was converted to the corresponding Lung-RADS score,of which 2 points was negative and 3 points or above was positive. Intraclass correlation coefficient(ICC) and Bland-Altman index were used to evaluate the interobserver consistency of diameter and volume measurements. Kappa analysis was used to evaluate the interobserver consistency of Lung-RADS score and the intergroup consistency of positive/negative.Results ICC analysis showed that the consistency of manual diameter measurement(0.994-0.996) was significantly lower than that of semi-automatic volume measurement(0.997-0.998),and Bland-Altman index analysis showed that the bias of manual diameter measurement was higher than that of semi-automatic volume measurement. Compared with manual diameter measurement,the use of semi-automatic volume measurement can significantly improve the consistency of Lung-RADS score and positive/negative classifications(0.963-0.975 and 0.957-0.977 vs. 0.833-0.866 and 0.863-0.892).Conclusion 3D-Slicer semi-automatic volume measurement can improve the interobserver consistency of the size measurement of solid pulmonary nodules, as well as the corresponding Lung-RADS categories.

    参考文献
    相似文献
    引证文献
引用本文

刘会佳,张瑜.肺实性结节半自动体积测量提高观察者间Lung-RADS评分一致性[J].重庆医科大学学报,2023,48(5):544-547

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2022-07-07
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-06-20
  • 出版日期:
文章二维码